Bulletin of the American Physical Society
APS March Meeting 2020
Volume 65, Number 1
Monday–Friday, March 2–6, 2020; Denver, Colorado
Session G28: Infrared Sensing and Imaging
11:15 AM–2:15 PM,
Tuesday, March 3, 2020
Room: 405-407
Sponsoring
Units:
FIAP GIMS
Chair: Carola Emminger, New Mexico State Univ
Abstract: G28.00005 : Mid-Wave Infrared Resonant Cavity Detectors
Presenter:
Gary W Wicks
(University of Rochester)
Author:
Gary W Wicks
(University of Rochester)
their large dark current and its noise-producing fluctuations. MWIR dark current is more than a million times that of short-wave (telecom) IR detectors. Several decades of work on dark current reduction via attention to material quality and epitaxial structure are nearing maturity. Significant improvements in dark current require new approaches. Our approach reduces dark current by reducing the volume of the detector’s absorber layer. A thin absorber layer is located inside an optical cavity formed by two mirrors – the so-called Resonant Cavity Detector (RCD). Optical absorption of the thin layer is typically ~1%, which would produce unacceptably small quantum efficiency (QE) in a single-pass detector. In an RCD, the light passes through the thin absorber many times (~50-100) as it re-circulates within the optical cavity, which produces good QE, and also low dark current. RCDs with QE~50% have achieved nearly 10× reduction in dark current and we expect to eventually reduce dark current by 100×.The RCD approach also affects frequency bandwidth (speed) and spectral bandwidth. RCDs absorbers are ~100× thinner than conventional detectors, which reduces minority carrier transit time, thus the frequency bandwidth is expected to increase to > 10 GHz. The spectral bandwidth, Δ, of RCDs is greatly reduced due to interference of the recirculating light with itself. RCDs with Δ ~ 20 nm have been produced, and Δ ~ 3 nm seems feasible. The narrow Δ and low dark current makes RCDs ideal for narrow band applications, such as detection of lasers or sensing spectrally sharp absorption features of gases. The RCD’s spectral response can be tuned 50-100 nm with detector temperature or the light’s angle of incidence. Finally, we discuss the tolerance on the epitaxial growth, which is significantly tighter for RCDs (1% layer thickness control) than for conventional MWIR detectors.
Follow Us |
Engage
Become an APS Member |
My APS
Renew Membership |
Information for |
About APSThe American Physical Society (APS) is a non-profit membership organization working to advance the knowledge of physics. |
© 2025 American Physical Society
| All rights reserved | Terms of Use
| Contact Us
Headquarters
1 Physics Ellipse, College Park, MD 20740-3844
(301) 209-3200
Editorial Office
100 Motor Pkwy, Suite 110, Hauppauge, NY 11788
(631) 591-4000
Office of Public Affairs
529 14th St NW, Suite 1050, Washington, D.C. 20045-2001
(202) 662-8700