48th Annual Meeting of the APS Division of Atomic, Molecular and Optical Physics
Volume 62, Number 8
Monday–Friday, June 5–9, 2017;
Sacramento, California
Session H3: Atomic and Nuclear Measurements in Ion Traps
10:30 AM–12:30 PM,
Wednesday, June 7, 2017
Room: 308
Chair: Thad Walker, University of Wisconsin
Abstract ID: BAPS.2017.DAMOP.H3.2
Abstract: H3.00002 : Ultrasensitive magnetometer using a single atom
11:00 AM–11:30 AM
Preview Abstract
Abstract
Author:
Christof Wunderlich
(University of Siegen)
Precision sensing, and in particular high precision magnetometry, is a central goal of research into quantum technologies. The precision, and thus the sensitivity of magnetometry scales as $1/\sqrt {T_2}$ with the phase coherence time $T_2$ of the sensing system. Typical quantum sensing protocols prolong $T_2$ of the quantum states used for sensing by using dynamical decoupling (DD), that is, applying a continuous or pulsed electromagnetic driving field. In the case of pulsed DD, the required repetition rate of pulses -- with each pulse having a well defined pulse area -- is proportional to the frequency of the field to be detected with high sensitivity, thus effectively limiting the frequency range of the sensor. To achieve a long coherence time $T_2$ using continuous DD,
the amplitude of the driving field has to be kept highly stable for time $T_2$, another technologically challenging problem.
Here, we implement a decoupling scheme using two continuous decoupling fields in an atomic 4-level scheme. Thus, the coherence time is no longer limited by fluctuations of the amplitude of the decoupling fields. Instead, $T_2$ is determined by the frequency stability of the driving fields which is straight forward to maintain with high precision using, for instance, a commercial atomic clock. Using a single trapped $^{171}$Yb$^+$ ion as a sensor, we experimentally attain a sensitivity of $4.6$ pT $/\sqrt{\mbox{Hz}}$, to our knowledge the best sensitivity so far realized with a single atom \footnote{I. Baumgart, J.M. Cai, A. Retzker, M.B. Plenio, C. Wunderlich, Phys. Rev. Lett. \textbf{116}, 240801 (2016).}. The detected magnetic field is an alternating-current (AC) magnetic field near 14 MHz. Based on the principle demonstrated here, this unprecedented sensitivity together with its tuneability from direct-current to the gigahertz range could be used for magnetic imaging in as of yet inaccessible parameter regimes.
To cite this abstract, use the following reference: http://meetings.aps.org/link/BAPS.2017.DAMOP.H3.2