Bulletin of the American Physical Society
92nd Annual Meeting of the Southeastern Section of the APS
Thursday–Saturday, October 23–25, 2025; Festival Conference and Student Center, James Madison University, Harrisonburg, Virginia
Session D01: Poster Session (4:00PM - 5:45PM)
4:00 PM,
Thursday, October 23, 2025
James Madison University
Room: Grand Ballroom
Abstract: D01.00062 : Optimization of Resonator Quality Factor and SNR for RASER Observation at Ultra-Low Magnetic Fields
Presenter:
Andrew K Maresca
(UNC Chapel Hill and UNC Biomedical Research Imaging Center)
Authors:
Andrew K Maresca
(UNC Chapel Hill and UNC Biomedical Research Imaging Center)
Sebastian W Atalla
(UNC Chapel Hill and UNC Biomedical Research Imaging Center)
Rosa T Branca
(UNC Chapel Hill and UNC Biomedical Research Imaging Center)
Radio-frequency Amplification by Stimulated Emission of Radiation (RASER) has been proposed as a strategy to recover spectral separation at low magnetic fields. Analogous to a laser, a RASER produces self-sustaining, coherent radio-frequency emission from nuclear spins with an inverted population coupled to a high-quality resonator. This effect drives the ensemble of spins into phase coherence and generates ultra-narrow spectral lines far sharper than those limited by transverse relaxation. The observation of RASER depends on the balance between transverse relaxation, the resonator quality factor (Q), and the degree of spin polarization (Mo). Because of this, the effect requires high resonator Q factors not typically seen at ultra-low field strengths and calls for improved optimization of circuit components.
The improvement of Q and subsequently SNR is highly dependent on hardware at lower field strengths. To increase the circuit’s performance capability and move towards observing RASER, electronic components were selected and optimized based on material and operating characteristics. Changes to the solenoid wire type and circuit layout were made to existing NMR coils and tested for both quality factor increases and noise level reduction. Here we present the optimization of NMR primary resonators to achieve unprecedented quality factors in excess of 100, and an improved signal-to-noise ratio of >1500. These improved values are a step towards observing RASER at ultra-low field.
Follow Us |
Engage
Become an APS Member |
My APS
Renew Membership |
Information for |
About APSThe American Physical Society (APS) is a non-profit membership organization working to advance the knowledge of physics. |
© 2025 American Physical Society
| All rights reserved | Terms of Use
| Contact Us
Headquarters
1 Physics Ellipse, College Park, MD 20740-3844
(301) 209-3200
Editorial Office
100 Motor Pkwy, Suite 110, Hauppauge, NY 11788
(631) 591-4000
Office of Public Affairs
529 14th St NW, Suite 1050, Washington, D.C. 20045-2001
(202) 662-8700