Bulletin of the American Physical Society
6th Joint Meeting of the APS Division of Nuclear Physics and the Physical Society of Japan
Sunday–Friday, November 26–December 1 2023; Hawaii, the Big Island
Session 4WCA: Data Acquisition System I
2:00 PM–3:30 PM,
Monday, November 27, 2023
Hilton Waikoloa Village
Room: Kings 3
Chair: Hidetada Baba
Abstract: 4WCA.00003 : The sPHENIX Data Acquisition System - the Experiment's first Run in 2023
3:00 PM–3:30 PM
Presenter:
Martin L Purschke
(Brookhaven National Laboratory)
Author:
Martin L Purschke
(Brookhaven National Laboratory)
Collaboration:
*For the sPHENIX Collaboration
The Data Acquisition System of sPHENIX is designed for event rates of 15 KHz. The largest data volume is produced by the tracking system, consisting of a Monolithic-active-pixel Vertex Detector (MVTX), an Intermediate Tracker (INTT), and the Time Projection Chamber (TPC). In order to achieve the design event rate, the entire tracking system will be read out in continuous, or streaming mode. The resulting continuously sampled signals from the tracking system must then be processed and correlated with the actually triggered data from the calorimeter system. Due to budget constraints, it was not possible to upgrade the entire readout, including the calorimeter systems, to a streaming-based one. However, by operating the entire tracking system in streaming mode, it will be possible to acquire tracking data without the calorimeters at a faster rate, which will benefit our heavy-flavor physics program under most running conditions.
At the time of this writing, we have commissioned the major parts of the data acquisition system, such as most readout systems for the various detector components, the Timing System, and most of the hardware of the Local-Level-1 Trigger system, and are now commissioning the detectors with beam. During the current commissioning phase we already routinely use physics-type signals, such as π0 invariant mass spectra and detector correlation plots, to evaluate the detector performance and calibrations.
We will give an overview of the sPHENIX experiment, its detector systems and their readout, and present the performance during data taking, the achieved statistics, and especially the state of combining the streaming readout of the tracking detectors with the triggered readout of the calorimeters and the Minimum-Bias Detector.
Follow Us |
Engage
Become an APS Member |
My APS
Renew Membership |
Information for |
About APSThe American Physical Society (APS) is a non-profit membership organization working to advance the knowledge of physics. |
© 2025 American Physical Society
| All rights reserved | Terms of Use
| Contact Us
Headquarters
1 Physics Ellipse, College Park, MD 20740-3844
(301) 209-3200
Editorial Office
100 Motor Pkwy, Suite 110, Hauppauge, NY 11788
(631) 591-4000
Office of Public Affairs
529 14th St NW, Suite 1050, Washington, D.C. 20045-2001
(202) 662-8700