Bulletin of the American Physical Society
APS Eastern Great Lakes Section (EGLS) Spring 2025 Meeting
Friday–Saturday, April 11–12, 2025; Wright State University, Dayton, Ohio
Session Q03: BioMedical, Astrophysics, Nuclear and Particle Physics
9:40 AM–10:52 AM,
Saturday, April 12, 2025
Wright State University
Room: Room 103, Oleman Hall
Chair: Jacob Callebs, Wayne State University; Jacob Callebs, Wayne State University
Abstract: Q03.00003 : Study of Oversized SPIO Nanoparticles with a Magnetic Particle Spectrometer for Suitability as MPI Tracers*
10:04 AM–10:16 AM
Presenter:
Chris Bastajian
(Oakland University)
Authors:
Chris Bastajian
(Oakland University)
Christopher Paul McDonough
(Oakland University)
Cody Hunt
(Oakland University)
Matthew Jurj
(Oakland University)
Alexey A Tonyushkin
(Oakland University)
Traditionally, single-core SPIO Vivotrax (Magnetic Insight) has been widely used in the MPI community, but recently, the nanoflower-shaped cluster SPIO Synomag-D 70 nm (Micromod, Germany) has become a popular MPI tracer due to superior performance. Other types of SPIO represent oversized clusters, which can be useful for in-vivo MPI. This study explores the suitability of oversized sphere shell SPIO clusters for MPI, specifically Magnefy and ProMag (BangsLab, IN, USA) with a hydrodynamic diameter ~1 µm. Our MPS technique involves applying 1 kHz AC magnetic fields with an amplitude up to 25 mT to the SPIO and detecting their magnetization responses M(H) in the frequency domain. The resulting M(H) curves demonstrated that Synomag-D and Vivotrax exhibit steep magnetization, corroborating exceptional MPI performance. In contrast, the M(H) curves of the oversized nanoparticles show lower magnetization saturation and a less steep magnetization response. Specifically, ProMag and Magnefy exhibit low third harmonic magnitudes compared to Synomag-D's magnitude at ~1.6 mT (Fig. 2). The Point Spread Functions (PSF) of the particles received by our MPS are also compared to the PSFs recorded using our MPI scanner. While its magnetization amplitude is not as high as Vivotrax and Synomag-D, Promag exhibits a full width half max (FWHM) characteristic that is close to that of Vivotrax. This makes Promag a suitable tracer for MPI with an acceptable image resolution.
**NIH under award R15EB028535 Center for Biomedical Research Oakland University
Follow Us |
Engage
Become an APS Member |
My APS
Renew Membership |
Information for |
About APSThe American Physical Society (APS) is a non-profit membership organization working to advance the knowledge of physics. |
© 2025 American Physical Society
| All rights reserved | Terms of Use
| Contact Us
Headquarters
1 Physics Ellipse, College Park, MD 20740-3844
(301) 209-3200
Editorial Office
100 Motor Pkwy, Suite 110, Hauppauge, NY 11788
(631) 591-4000
Office of Public Affairs
529 14th St NW, Suite 1050, Washington, D.C. 20045-2001
(202) 662-8700