Bulletin of the American Physical Society
65th Annual Meeting of the APS Division of Plasma Physics
Monday–Friday, October 30–November 3 2023; Denver, Colorado
Session BP11: Poster Session I:
Fundamental: Magnetic Reconnection; Dusty plasmas & Nanoparticle synthesis
ICF measurement and analysis
Space plasma physics
MFE: Disruptions avoidance and mitigation; Whole device modeling and reactor technologies
9:30 AM - 12:30 PM
Monday, October 30, 2023
Room: Plaza ABC
Abstract: BP11.00044 : Self-radiometric calibration solution for tokamak's optical diagnostics*
Presenter:
Vincent Carrat
(Bertin technologies)
Authors:
David A Anthoine
(Bertin Technologies)
Slim Hamdani
(Bertin Technologies)
Vincent Carrat
(Bertin technologies)
Maarten De Bock
(ITER Organization)
Optical systems installed in particularly harsh environment will likely see their optical throughout degrades over time due to optics damages. A shutter and a cleaning system can be implemented to protect optics but won’t fully prevent throughout losses. As a consequence, the transmission of the system needs periodic recalibration.
It’s not possible to permanently install a calibrated light source in front of the system, so one solution is to place a retroreflector behind the shutter to do the calibration remotely. Various retroreflectorbased solution have been proposed, but since they rely on knowing the reflectivity on the material, they are not immune against environment aggressions. As a consequence, the calibration will drift over time.
Many variants of design have been proposed in order to calibrate the retroreflector itself but without guaranteeing the radiometric calibration.
We propose an innovative solution that offers a true radiometric calibration based on dual-shape retroreflector. It combines two types of mirrors with different effects. The first returns the light like a corner cube after three reflections while the seconds induce a diffusing effect with a single reflexion. The difference in reflection number associated with a different optical conjugation allows the measurement of the intrinsic reflectivity of the material of the retroreflector as well as the transmission of the optical system. Such reflector has been implemented in the design of the CXRS core diagnostic for F4E/ITER. It has been demonstrated that both signals can be separated and detected with enough SNR to get a self-calibration of the reflector and thus a true calibration of the transmission optical path.
The views and opinions expressed herein do not necessarily reflect those of the ITER Organization.
*The work leading to this publication has been funded by Fusion for Energy under F4E-OMF-847-Task Order 2. This publication reflects the views only of the author, and Fusion for Energy cannot be held responsible for any use which may be made of the information contained therein.
Follow Us |
Engage
Become an APS Member |
My APS
Renew Membership |
Information for |
About APSThe American Physical Society (APS) is a non-profit membership organization working to advance the knowledge of physics. |
© 2024 American Physical Society
| All rights reserved | Terms of Use
| Contact Us
Headquarters
1 Physics Ellipse, College Park, MD 20740-3844
(301) 209-3200
Editorial Office
100 Motor Pkwy, Suite 110, Hauppauge, NY 11788
(631) 591-4000
Office of Public Affairs
529 14th St NW, Suite 1050, Washington, D.C. 20045-2001