Bulletin of the American Physical Society
60th Annual Meeting of the APS Division of Plasma Physics
Volume 63, Number 11
Monday–Friday, November 5–9, 2018; Portland, Oregon
Session PP11: Poster Session VI: Relativistic Laser Plasma Interaction and Beam Physics; Boundary; MHD and Stability, Transients; FRC; Dusty Plasmas; Basic Studies; Computational and Diagnostic Methods (2:00pm-5:00pm)
Wednesday, November 7, 2018
OCC
Room: Exhibit Hall A1&A
Abstract ID: BAPS.2018.DPP.PP11.96
Abstract: PP11.00096 : Increased ionization efficiency for high performance CT injection
Presenter:
Fumiyuki Tanaka
(Nihon University)
Authors:
Fumiyuki Tanaka
(Nihon University)
Tomohiko Asai
(Nihon University)
Thomas Roche
(TAE Technologies, Inc.)
Ian Allfrey
(TAE Technologies, Inc.)
Hiroshi Gota
(TAE Technologies, Inc.)
Tadafumi Matsumoto
(TAE Technologies, Inc., Univ of California - Irvine)
Toshiki Tajima
(TAE Technologies, Inc., Univ of California - Irvine)
and the TAE Team
(TAE Technologies, Inc.)
A magnetized coaxial plasma gun (MCPG) is one of the devices used to generate and accelerate a compact toroid (CT) with a spheromak-like magnetic configuration. A typical MCPG consists of a set of axisymmetric cylindrical electrodes, a bias coil, and gas-puff valves; and it requires excessive neutral gas to obtain breakdown. The excess gas degrades the performance not only of the generated CT but also of the target plasma. By using a pre-ionization (PI) system (a miniature gun that is installed radially at the same cross section as the gas-puffing ports) we have succeeded in reducing the amount of neutral gas required (~40%) for breakdown, which results in improved performance of ejected CTs [1]. For further improvement of the CT performance, we focus on the gas flow and its spatial distribution in the miniature gun as well as MCPG. The breakdown condition of the miniature gun is optimized by changing the distance between electrodes and varying the amount of initial enclosed gas. A simulation of the gas flow is conducted to optimize the geometry of gas inlets on the miniature gun. We will present an updated PI system and effects on the ejected CT. [1] T. Edo et al., J. Plasma Fusion Res. 13, 3405062 (2018).
To cite this abstract, use the following reference: http://meetings.aps.org/link/BAPS.2018.DPP.PP11.96
Follow Us |
Engage
Become an APS Member |
My APS
Renew Membership |
Information for |
About APSThe American Physical Society (APS) is a non-profit membership organization working to advance the knowledge of physics. |
© 2024 American Physical Society
| All rights reserved | Terms of Use
| Contact Us
Headquarters
1 Physics Ellipse, College Park, MD 20740-3844
(301) 209-3200
Editorial Office
100 Motor Pkwy, Suite 110, Hauppauge, NY 11788
(631) 591-4000
Office of Public Affairs
529 14th St NW, Suite 1050, Washington, D.C. 20045-2001
(202) 662-8700